People call me while they are shopping and say, "I notice you have non-backwashing and backwashing. What's the difference?" Here is the short version I give on the phone. A backwashing acid neutralizer has an electric valve on top that reverses the flow about once a week and sends about 140 gallons down a drain on the 2.5 cubic foot size. A non-backwashing acid neutralizer has a plain head with an inlet and an outlet. No drain, no electricity. The calcite inside is the same, and the pH comes up the same. The only reason to pay for the backwashing tank is iron above 0.5 ppm, or heavy sediment.

A backwashing acid neutralizer with a black electric valve on top beside a non-backwashing acid neutralizer with a plain head and two red bypass knobs, both tanks the same height

Caller "What's the difference in an acid neutralizer that backwashes, which is what I have right now, and an acid neutralizer that doesn't backwash? I've been doing it for 30 years, and I hear it at nighttime when I'm trying to sleep downstairs."

Aidan

Aidan "99% of the time, people nationwide choose the non-backwashing because it doesn't require dumping 140 gallons of water out of the discharge line. It doesn't need electric, and it's installed as an upflow. It's like it's being rinsed or backwashed every time you use water, but there's no discharge, and there's no water wasted."

A Maryland caller this September, with a 25-year-old backwashing tank he can hear cycling at night. This page is the long version of what I told him.

Quick Answer

If your only problem is low pH, you want the non-backwashing (upflow) acid neutralizer. A backwashing acid neutralizer is the one you need when your pH is below 7 and your iron is above 0.5 ppm, or when heavy sediment has to be rinsed out of the tank.

  1. Both raise the pH the same. Same calcite, same tank. The difference is the head on top and which way the water moves. See where the water goes in each tank.
  2. Backwashing is for iron and sediment. An acid neutralizer does not need to backwash unless your iron is above 0.5 ppm, or heavy sediment would collect in the calcite. See when you need the backwashing tank.
  3. The backwashing tank costs $400 to $700 more for the same size, plus a drain line and an outlet, and sends about 140 gallons down the drain each cycle on the 2.5 cubic foot size. See what it costs to own.
  4. The calcite does not harden in a Vortech tank without a backwash. Water lifts through the whole bed every time you run a tap. See will the calcite get hard.

How to tell which one you have

Look at the top of the tank. A backwashing acid neutralizer has a black electric valve with a display, a power cord, and a drain line running off it. A non-backwashing acid neutralizer has a short black head with two red knobs and nothing else attached. The tanks underneath are the same. You can also hear the difference: the caller in the opening hears his backwash run at night, because the valve on a backwashing tank is a motor on a timer. The non-backwashing head has no motor, no timer and no cord.

Fleck 2510SXT 2.5 cubic foot backwashing acid neutralizer: a tall tank with a black electric control valve and display on top Clack 2.5 cubic foot non-backwashing acid neutralizer: the same tank with a short black head, two red bypass knobs and five bags of calcite beside it
The backwashing tank, with the Fleck 2510SXT electric valve on top, and the non-backwashing tank, with the plain Clack head. Same 2.5 cubic foot Vortech tank, calcite included with both. Tap either photo for its product page.

Where the water goes in each tank

Both tanks hold the same calcite and raise the pH the same way. What differs is which direction the water moves through the calcite, and whether the tank ever reverses that flow to a drain.

Non-backwashing (upflow) acid neutralizers

In an upflow system, water enters the bottom of the tank through the distributor tube, rises up through the entire calcite bed, and exits through the control head at the top. The way I put it on the phone: the water comes into the unit, goes down the center tube, up through the Vortech plate (a slotted plate in the bottom of the tank that takes the place of gravel), and the way the slits are cut in the plate, it moves the water in a circular direction up through the bed. So it is like the calcite is being rinsed every time you use water, but there is no discharge and no water wasted. Nothing on the head moves. There is an inlet and an outlet, and that is it.

Backwashing (downflow) acid neutralizers

In a downflow system, water enters at the top of the tank during normal operation, flows down through the calcite bed, and exits through the distributor tube at the bottom. The electric valve on top, a Fleck 2510SXT on the ones I sell, has a 7-day timer. At least once a week it puts itself into a backwash: it reverses the flow, pushes water up from the bottom to lift and rinse the calcite, and sends that water out a drain line. On the 2.5 cubic foot tank one cycle sends about 140 gallons down the drain. The number of days between backwashes is a setting on the valve, called Day Override in the Fleck manual.

Three cutaway views of the real tanks. Non-backwashing: water goes down the center tube and up through all the calcite every time a tap runs, nothing to a drain. Backwashing in service: water goes down through the calcite and up the center tube. Backwashing during the weekly rinse: flow reversed, about 140 gallons out the drain hose on the 2.5 cubic foot tank
Inside the two tanks. The non-backwashing tank rinses itself upward every time you run water, with nothing sent to a drain. The backwashing tank runs downward in service and reverses about once a week, sending about 140 gallons out the drain hose. Tap to enlarge.

I filmed the two tanks side by side so you can see the heads and hear the whole answer in 2 minutes.

When you need the backwashing tank

I recommend non-backwashing acid neutralizers for the vast majority of homes. When your pH is below 7 and your iron is above 0.5 ppm, the neutralizer has to be the backwashing Fleck 2510SXT. The other reason is heavy sediment that clogs fixtures and overwhelms a sediment filter. How low the pH is does not decide it. A pH of 5.5 and a pH of 6.8 both get the same tank; the pH decides whether I blend a little FloMag (a pH booster) in with the calcite, not whether the tank backwashes. The iron does. Here is why: an iron filter needs a pH of 8 to 8.5 to remove iron and manganese properly, so the neutralizer goes ahead of the iron filter and brings the pH up first. That means the iron is still in the water when it passes through the calcite, and iron that collects in calcite has to be rinsed out to a drain. The non-backwashing tank has no way to do that.

What your water test shows Which acid neutralizer Why
pH below 7, iron 0.5 ppm or less, clear water Non-backwashing (upflow) Nothing to rinse out. 99 of every 100 of my acid neutralizer customers buy this one.
pH below 7 and iron above 0.5 ppm Backwashing (Fleck 2510SXT), ahead of the iron filter The iron filter needs a pH of 8 to 8.5, so the neutralizer goes first. Iron caught in the calcite has to be rinsed out to a drain.
pH below 7 and heavy sediment that clogs a sediment filter Backwashing (Fleck 2510SXT) The weekly rinse carries the dirt out to the drain. Rare, but it happens on some wells.

A caller this June with a neutralizer and a softener asked me straight out, "But how do I know if I need a backwash or non-backwash?" I asked him, "Do you have iron in the water?" He said, "Yes, I do. A lot of iron." Then you have to go with the backwashing, our Fleck 2510 backwashing unit. That is the whole test: pH under 7, iron over 0.5 ppm, backwashing. A Maine caller in July with a pH of 5.6 to 5.8 and no iron problem to speak of asked the other way, "And you don't need the backwashing?" No. The only time I recommend backwashing is high levels of iron or heavy, heavy sediment that clogs fixtures up. I recommended the 2.5 cubic foot non-backwashing, and he told me, "I like the fact of not having the backwash, 'cause that is a problem with some of these."

Well water test kit: certified lab analysis of 53 contaminants
Already have a lab report? Skip this. No iron number yet: certified lab test, $199

One lab test reports pH plus iron

The decision above needs two numbers, pH and iron. One certified lab test, mailed to you, run by an accredited lab, reports both from one sample.

Send me the report when it comes back and I will tell you which tank.
Aidan, Mid Atlantic Water
Have your pH and iron numbers?

Text me your test results

Send the pH and iron lines from your report, or a photo of the tank you have now. I answer myself.

8 AM to 5 PM Eastern, seven days a week. A real person, not a call center.

Will the calcite get hard without a backwash?

No. In a Vortech tank the water lifts through all the calcite every time you run a tap, so the calcite never packs down. This is the argument you will hear for the backwashing tank, that the calcite will harden or channel without a weekly rinse. Channeling means the water finds one easy path through the calcite and skips the rest. Here is what I tell callers who ask. The Vortech plate moves the water in a circular motion, so it gets better coverage and better contact time with the calcite, and it eliminates any channeling or solidification. A backwashing system cannot do that, because channeling starts at the top, and the backwash is not strong enough to lift and move the bed around. A bag of calcite weighs about 60 pounds dry and close to 75 pounds wet, there are 3 to 5 bags in the tank, and you only have 40 to 60 psi coming off your well tank. The weekly backwash is a slow rinse. It is not lifting the bed up off the base of the tank, and it does not undo channeling that has already happened.

A caller in August had an older mechanical Fleck backwashing neutralizer, 20 years old by his guess, leaking to the drain, and asked me, "Why do they have a backwash? What's the point of the backwash? Just to move the aggregate or what?" The honest answer is the one above: it is a slow rinse for iron over 0.5 ppm or heavy sediment, and if you have neither, it is doing nothing for you. One of my buyers who swapped an old backwashing system for the 1.5 cubic foot upflow wrote that it had been wasting a lot of water and had channeling issues, and finished with, "Upflow is the way to go."

What the backwashing tank costs to own

The backwashing acid neutralizer costs $400 to $700 more than the non-backwashing tank of the same size, and that is before the drain line, the outlet, and the water. These are my prices today, with the calcite included.

Tank size Non-backwashing (Clack) Backwashing (Fleck 2510SXT) Difference
1.5 cubic foot (10 x 54) $1,295 $1,695 $400
2.0 cubic foot (12 x 52) $1,395 $2,095 $700
2.5 cubic foot (13 x 54) $1,495 $2,195 $700

Then the backwashing tank needs three things the other one does not. A drain: the discharge line has to go somewhere, a sanitary tub, outside, or straight into your septic system. Electricity: a standard outlet near the tank for the valve. And the water itself: about 140 gallons down the drain each cycle on the 2.5 cubic foot 2510SXT, at least once a week. When people find out how much water it actually discharges, a lot of them do not want that extra water going into their septic system. Most of the people who call me for a non-backwashing tank had a backwashing one before, and what they did not like was those 100-plus gallons per regeneration.

Two more things worth knowing about the electric valve. In a power failure the Fleck SXT valve keeps its clock for about 48 hours and will not start a backwash without power; if it misses a scheduled one it runs the next day. And the valve is a wear part. The August caller's old Fleck valve was leaking to the drain, and the choices I gave him were a rebuild kit at about $250 to $260, a replacement valve at about $500, or converting the tank to upflow, which is the next section. The non-backwashing head has nothing in it to rebuild.

Adding calcite is the same job on both tanks; the FAQ below covers how often. The cost guide has the full ownership numbers.

Converting a backwashing tank to upflow

Clack C1190 upflow control head: a short black head with a bypass valve, the part that replaces the electric valve on a backwashing tank
The Clack C1190 upflow head, $145. It replaces the electric valve on your existing tank. Tap the photo for the product page.

If you own a backwashing tank and your iron is 0.5 ppm or less with no sediment problem, you can keep the tank and swap the electric valve for a Clack C1190 upflow head. That is what I told the August caller with the leaking Fleck valve: with your existing tank, you can just get the head and convert it to a non-backwashing tank, instead of a $500 valve or a $250 rebuild kit. One thing to know if your old tank has gravel in the bottom instead of a Vortech plate: a gravel-bedded tank cuts your flow rate about 25% compared with a Vortech tank. If the tank is old enough that you are tired of it, the whole 2.5 cubic foot non-backwashing tank with five bags of calcite is $1,495.

One of the buyers of that head had done it the other way around years earlier. He wrote in 2024: "I should have listened to Aiden in the beginning when he recommended a moving parts free up flow system over the electro-mechanical backwashing valve that I 'thought' I wanted. He was there for me and supporting his products some 10+ years after my initial purchase."

What buyers wrote about each type

These are verified purchases from the reviews on my product pages, newest first, in the buyers' own words. Reviewer names appear as the buyers wrote them.

Buyer Bought What they wrote
Anonymous, Jun 2024 Verified buyer Clack C1190 upflow head, to convert a backwashing tank "I should have listened to Aiden in the beginning when he recommended a moving parts free up flow system over the electro-mechanical backwashing valve that I 'thought' I wanted."
Kelly, Mar 2024 Verified buyer Clack 2.5 non-backwashing, pH about 5 "I am curious how this non-backwashing system will endure ... I also wonder when calcite needs to be replenished, if I will need to wash the tank to clean any silt that gets past the 5 micron pre-filter."
Dale H., Apr 2022 Verified buyer Clack 2.5 non-backwashing, between a backwashing iron filter and a softener "No moving parts and it does exactly what it's supposed to do. The hardest part is getting the Calcite into the tank. Raised my PH from 6.8 to a perfect 7.6!"
Mitchell C., Aug 2021 Verified buyer Clack 1.5 non-backwashing, replacing an older backwashing system "Immediatly adjusted ph from 6.5 to 7.2. I was wastind a lot of water backwashing and has a l I t od channeling issues with backwashing. Upflow is the way to go."
james d., Jul 2020 Verified buyer Clack 2.5 non-backwashing "It was exactly what we needed compared to all the others trying to sell us a backwashing system that we did not need nor the electronic Timer etc."
Thomas S., Mar 2020 Verified buyer Fleck 2510SXT 1.5 backwashing "The Vortech tank works very well; the side port makes it easy to add media. Its cool to watch the nedia swirl up during backwash. The Fleck controller is fairly easy to program although not all parameters are explained adequately. Been trouble free for 3.5 years so far."
Rick C., Mar 2020 Verified buyer Clack 1.5 non-backwashing, replaced a Sears motorized backwasher "Previous model was wasting 100s of gallons of precious well water each cleaning once a week. That was if the unit didn't reset to the default of twice a week each time there was a power outage or bump ... Also had to run a drain hose across the basement to a drain."

Kelly's question about silt is the right one, and the answer is the 5 micron sediment filter she already has ahead of the tank. Beyond that, the upkeep on either tank is the same: adding calcite. Thomas's backwashing tank is the case where it fits: he later switched that same tank over to iron and manganese media, which is exactly the job a backwashing valve is for.

Frequently asked questions

How often should I backwash an acid neutralizer?

At least once a week. The valve has a timer, and you set how many days it waits between backwashes; on the Fleck 2510SXT tanks I sell it is set to 7. A non-backwashing tank never backwashes; the upflow rinses the calcite every time you run water.

How to maintain an acid neutralizer system?

Add calcite as it dissolves. On a 2.5 cubic foot tank that is a 50-pound bag about every 2 to 3 years, poured in through the fill port on the side. Both tanks have the same calcite schedule; the backwashing tank also has an electric valve to keep an eye on. The servicing guide has the steps.

What do you put in an acid neutralizer?

Calcite, a natural limestone, in 50-pound bags. The 2.5 cubic foot tank holds five bags; they ship in separate bags and are loaded at install. A 50-pound bag of calcite is $145 shipped. For very low pH I blend in a little FloMag.

How long do acid neutralizers last?

Two of my callers this year had backwashing tanks 25 and about 20 years old; the second one's Fleck valve had started leaking to the drain. You replace the calcite, not the tank. The electric valve on a backwashing tank is the one part that wears out.

Is an acid neutralizer necessary?

If your well water pH is below 7, yes. Corrosion starts slowly at 6.9 and gets worse the lower the pH goes, and the blue-green stains and pinhole leaks in copper pipe are the signs. The signs of acidic water page shows what to look for and what the fix looks like.

Is an acid neutralizer the same as a water softener?

No. An acid neutralizer raises pH by dissolving calcite into the water. A water softener removes hardness with resin and salt. Because the calcite adds some hardness, some homes end up with both, neutralizer first. The acid neutralizer and water softener page explains when you need both.

Aidan Walsh
About the author

Aidan Walsh

Aidan Walsh has spent 32 years in residential water treatment, the first stretch of it installing and servicing well systems before Mid Atlantic Water became an online supplier. Mid Atlantic Water is a family company; every recommendation on this site is based on what actually failed in the field and what fixed it. If you have a question this page did not answer, call or text him.